Diskriminasi lan ndandani kesalahan umum ing FanC.
Gagal SVM: Tampilan LED 2, kepiye mbusak weker. Gagal SPM: Tampilan LED 19, Kepiye mbusak weker?
Kode Alarm SVM 2.
(1) Konten: Konverter Frekuensi ngontrol voltase sumber daya sing sithik.
(2) Penyebab utama lan cara penghapusan.
(A) negesake 3 - voltase input Fase amplifier (kudu luwih gedhe tinimbang utawa padha karo voltase input input).
(b) negesake output voltase 8v saka PSM (normal: 22.8v utawa luwih).
(c) Konfirmasi Konverter, Kabel (Cxa2a / B).
(d) Ganti SVM.
Kode Alarm SPM 19, 20.
Voltase offset saka sampeyan Phase (Kode Alarm 19) lan V Fase (Alarm Code 20) sirkuit deteksi saiki uga akeh banget.
Nalika weker ana, monggo ngganti SPM. Nalika Dewan sirkuit SPM dicithak mung diganti, mangga konfirmasi sisipan konektor ing antarane unit listrik lan spa ngontrol papan sirkuit dicithak.






Fokus kanggo nyedhiyakake solusi Mong Pu sajrone 5 taun.